Publication 1756-UM522B-EN-P - February 2003
B-100 1756-DMD30 Specific Information
789
Xsync Out 1
Sync Generator 32 bit output register. Latched to parameter
788 [Xsync In 1] every time bit 0 of parameter 786 [Xsync
Status] (Sync Pulse) is set.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Position Control
Sync Generator
790
Xsync In 2
32 bit integer input of the Sync Generator. Latched to
parameter 791 [Xsync Out 2]. Link any 32 bit integer parameter
to this input parameter.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
Position Control
Sync Generator
791
Xsync Out 2
Sync Generator 32 bit output register. Latched to parameter
790 [Xsync In 2] every time bit 0 of parameter 786 [Xsync
Status] (Sync Pulse) is set.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Position Control
Sync Generator
792
Xsync Out 2 Dly
Displays data of parameter 791 [Xsync Out 2] from the last
sync period.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Position Control
Sync Generator
793
Xsync In 3
32 bit integer input of the Sync Generator. Latched to
parameter 794 [Xsync Out 3]. Link any 32 bit integer parameter
to this input parameter.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0
-8
8
Linkable, Read-Write, Floating Point
Position Control
Sync Generator
794
Xsync Out 3
Sync Generator 32 bit output register. Latched to parameter
793 [Xsync In 3] every time bit 0 of parameter 786 [Xsync
Status] (Sync Pulse) is set.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0
-8
8
Non-Linkable, Read Only, Floating Point
Position Control
Sync Generator
795
Xsync Out 3 Dly
Displays data of parameter 794 [Xsync Out 3] from the last
sync period.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0
-8
8
Non-Linkable, Read Only, Floating Point
Position Control
Sync Generator
No.
Name
Description
Values
Summary of Contents for ControlLogix 1756-DMD30
Page 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Page 4: ......
Page 8: ...Publication 1756 UM522B EN P February 2003 4...
Page 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Page 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Page 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Page 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Page 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...