Publication 1756-UM522B-EN-P - February 2003
1756-DMD30 Specific Information B-151
2204
Out Curr Rating
Enter the Power Module rated DC output Amps, from the
Power Module’s nameplate.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Amps
1
1
32767
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Drive Config
2205
Curr Xfmr Ratio
Defines the input to output ratio of the current transformer in
the Armature Power Module.
Default:
Min:
Max:
Type:
File:
Group:
1
1
32767
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Drive Config
2206
Field AC In Volt
Enter the nominal voltage at the Field Power Module input. If
an isolation transformer is used, enter the secondary voltage.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Volt
1
1
32767
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Drive Config
2207
Fld OutCurrRatng
Enter the Field Power Module's DC Amps output rating. This
value can be found on the Power Module's nameplate.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Amps
15
1
327.67
Non-Linkable, Read-Write, 16-bit Integer
Monitor
Drive Data
2208
Anlg Tach Volts
Enter the tachometer voltage that will be present when the
motor is turning at the speed specified in parameter
2181[Overspd Trip Pt].
Units:
Default:
Min:
Max:
Type:
File:
Group:
Volt
5
5
327.67
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Drive Config
No.
Name
Description
Values
Summary of Contents for ControlLogix 1756-DMD30
Page 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Page 4: ......
Page 8: ...Publication 1756 UM522B EN P February 2003 4...
Page 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Page 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Page 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Page 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Page 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...