Rockwell Automation Publication 2094-IN005H-EN-P - October 2012
Line Interface Module
35
Wiring the VAC LINE (IPL) Connector
Figure 30 - Line Interface Module (IPL connector)
Table 16 - VAC LINE (IPL) Connector
(catalog numbers 2094-AL09, 2094-AL
xx
S, 2094-BL
xx
S, and 2094-XL75S-C
x
)
Table 17 - VAC LINE (IPL) Connector
(
2094-BL02 module)
L3
L2
L1
1 2 3 4
Line Interface Module, Top View
(catalog number 2094-XL75S-C
x
is shown)
ATTENTION:
The input power for Bulletin 2094 line interface modules must come from
a grounded configuration. When an ungrounded power configuration is used, phases
L1, L2, and L3 (without a reference to earth ground) can drift and stress the line filter
components internal to the line interface module.
ATTENTION:
Your Bulletin 2093, 2094, and 2099 servo-drive user manual includes
examples of grounded and ungrounded power configurations. See
Additional
Resources
on
page 56
for publication numbers.
3-phase Supply
IPL Pin
Signal
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
L1
4
L1
2.5…25
(14…4)
16.0
(0.63)
2.7
(24)
L2
3
L2
L3
2
L3
1
3-phase Supply
IPL Pin
Signal
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
L1
1
L1
4.0
(12)
10.0
(0.38)
1.5…1.8
(13.2…15.9)
L2
2
L2
L3
3
L3
4
Summary of Contents for 2094-AL09
Page 57: ...Rockwell Automation Publication 2094 IN005H EN P October 2012 Line Interface Module 57 Notes...
Page 58: ...Rockwell Automation Publication 2094 IN005H EN P October 2012 58 Line Interface Module Notes...