Rockwell Automation Publication 2094-IN005H-EN-P - October 2012
Line Interface Module
7
Observe these guidelines when a 2094-AL
xx
S, 2094-BL
xx
S, or 2094-XL75S-C
x
line interface module is used in the system and mounted right of the drive with
the AC (EMC) line filter mounted behind the line interface module:
•
The clean zone (C) is to the left and beneath the drive system (gray
wireway).
•
The dirty zone (D) is to the right and above the drive, and above and
below the line interface module (black wireway).
•
The very dirty zone (VD) is from the filter output to drive. Shielded cable
is required on the EMC filter (LOAD side) and the braided shield
attached to the clamp (when provided).
•
The sercos fiber-optic cables are immune to electrical noise.
Figure 4 - Establishing Noise Zones (EMC filter behind the line interface module)
(1) If the drive system I/O cable contains (dirty) relay wires, route cable with the module I/O cable in dirty wireway.
(2) When space does not permit the 150 mm (6.0 in.) segregation, use a grounded steel shield instead. For examples, see the System
Design for Control of Electrical Noise Reference Manual, publication
GMC-RM001
.
(3) The Kinetix 6000 drive is shown as an example of any drive or other device in configuration with the line interface module; however,
noise zones of other products will vary.
(4) Only the 2094-AL
xx
S and 2094-XL75S-C
x
line interface modules are compatible with 2094 mounting brackets. The 2094-BL
xx
S,
2094-AL09, and 2094-BL02 line interface modules are not compatible.
C
D
D
D
VD
C
VD
D
D
D
PR
PR
MAIN VAC
I/O
(1)
and Feedback Cables
No sensitive
equipment within 150
mm (6.0 in.)
(2)
Line Interface Module
(catalog number
2094-AL
xx
S is shown)
Drive/System Module
(3)
Clean Wireway
Dirty Wireway
Motor Power Cables
Very dirty Filter/Drive connections
segregated (not in wireway)
Route 24V DC I/O
Shielded Cable
Route Encoder/Analog/Registration
Shielded Cables
2094 Mounting
Brackets
(4)
x2
VAC LOAD
VAC LINE
AC (EMC)
Line Filter
Control VAC
Auxiliary VAC
24V DC Brake
LIM
I/O