EU marking description
CE Conformity Marking:
CE
(2460)
Identification
Number of Notified
Body involved in production control stage:
2460
Explosion Protection marking:
Equipment Group:
-/II
Equipment Category:
2 G
The equipment is intended for Zone 1 and Zone 2. The space inside the process vessel and process
lines are considered as non-hazardous area therefore (-/II) in the marking code.
Equipment Category Definition
EU
Category
Equipment
Group
Typical Zone of
application
Gas atmospheres "high level of
protection"
2G
II
1
Gas atmospheres "normal level of
protection"
3G
2
No Ex protection.
-
-
Out of hazardous zone
Specific Conditions of Use
“X” - The flameproof joints not intended to be repaired.
“X” – Ambient temperature -20ºC to +60ºC
“X” – Minimum yield stress of the fastening screws used for enclosure is 646 MPa.
“X” – To avoid potential electrostatic charging hazard, always use a damp cloth for cleaning the
insulation jacket. Avoid dry rubbing of the insulation jacket.
“X” – The cable glands provided are suitable only for fixed applications and the cable must be
effectively clamped and cleated to prevent pulling and twisting.
Applicable Stand
ards
EN 60079-0:2012/A11:2013 (IEC 60079-0 ed.6.0)
EN 60079-1:2014 (IEC 60079-1 ed.7.0)
EN 60079-18:2008 (IEC 60079-18 ed. 4.0)
IEC 60079-7:2017, Edition: 5.1
EN IEC 60079-7:2015/A1:2018
Summary of Contents for TORREXX TX240
Page 52: ...APPENDIX A TECHNICAL INFORMATION ...
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 80: ...ASCO Valve used by Algas SDI ...
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......