6-35
ASDI
Operations and Maintenance – TX Models – P/N: 54629
Full Load Current Check
NOTE
See fusible link detail below for typical fusible link installation.
WARNING
These tests include high voltage. Exercise great caution when
performing the following tests. Carelessness could result in severe
injury or death. L1 ALWAYS ENERGIZED. See additional warnings
located at the beginning of this chapter.
Measure the current on each of the heater AC power input wires.
See data sheet
on page 6-36 or rating
plate
on the vaporizer for the correct line current for your
vaporizer. All wires should have readings equal to +10/-18% of the value listed
on the rating plate.
Low current on all wires indicates low input voltage. Drastically different current
readings may indicate a defective heater, defective wiring, or an open fusible link
due to overheating. If a fusible link is open, contact the factory. Do not attempt to
repair it.
Figure 13 – Full Load Current Check
VIEW OF
FUSIBLE LINK
IN NORMAL
CONDITIONS
VIEW OF
FUSIBLE LINK
IN OPEN
CONDITION
COPPER STRIP
MEASURE
CURRENT
POWER INPUT
WIRING
AMP CLAMP
POWER IN
POWER
DISTRIBUTION
BLOCK
FUSIBLE LINKS