32
C U E
S t a r t
T i m e
Only displayed when Cue menu option,
L
0 0 : 0 0 : 0 0 : 0 0 . 0 0
Use Times is set to on. The time code
displayed is for the current cue, selected in
the Cue menu. If the cue start time is
modified by the Set/Hold or capture
process, then the start time in the Cue
menu will be updated. The cue start time
is normally read from the ADAT tape
header and is referred to in other Alesis
documentation as song SMPTE Start
Offset. The cue start time is used with the
tape start time to calculate the AI -2 ADAT
offset time. The cue start time is a high
resolution time code number, which
includes subframes.
T a p e
S t a r t
T i m e
Only displayed when Cue menu option,
L
0 0 : 0 0 : 0 0 : 0 0 . 0 0
Use Times is set to on. The time displayed
is for the current cue, selected in the Cue
menu. If the tape start time is modified by
the Set/Hold or capture process, then the
current tape time in the Cue menu will be
updated. The tape start time is normally
read from the ADAT tape header. The
tape start time is used with the cue start
time to calculate the AI-2 ADAT offset time.
The tape start time is a high resolution time
code number, which can include
subframes and 0-15 subframe sample
steps. The AI -2 does not display the
sample steps but uses them in the offset
calculation.
O f f s e t
The AI-2 ADAT offset. This is the
L
0 0 : 0 0 : 0 0 : 0 0 . 0 0
difference between ADAT tape time and
the time code number that the AI-2 will
generate or return to the controller. If the
Cue menu option Use Times option is on,
this offset will be automatically calculated
from the cue start time (SMPTE start
offset) and tape start time (ADAT tape
start) times. If the offset is modified by the
Set/Hold process, then the cue start time in
the Cue menu will be updated. The offset
is a high resolution time code number,
which can include subframes.