System Specifications
52
7750 SR-a4 and SR-a8 Installation Guide
Notes:
1.
Short-term refers to no more than 96 consecutive hours per occurrence and no more than 15 occurrences in
a one-year period.
2.
Pollution degree is as defined in IEC 60950. Pollution Degree 2 applies where there is only non-conductive
pollution that might temporarily become conductive due to occasional condensation.
Power Supply Unit Module Specifications
Rated voltage (DC)
–48 VDC
Operating voltage range (DC)
–40 to –72 VDC
Rated voltage (AC)
120 or 240 VAC
Operating voltage range (AC)
90 to 264 VAC
Table 16: 7750 SR-a8 Environmental Specifications (Continued)
Parameter
Description
Table 17: AC PSU Specifications
Parameter
Description
Dimensions (H x W x D)
3.4 x 7.78 x 1.59 in. (8.64 x 19.77 x 4.05 cm)
Weight
2.33 lb (1.06 kg)
Voltage range
90 to 264 VAC
Maximum current
12 A
Efficiency
93%
Table 18: –48 VDC PSU Specifications
Parameter
Description
Dimensions (H x W x D)
3.4 x 7.78 x 1.57 in. (8.6 x 19.77 x 3.99 cm)
Weight
2.44 lb (1.108 kg)
Voltage range
–40 to –72 VDC
Maximum current
40 A
Efficiency
93%
Summary of Contents for 7750 SR-a4
Page 8: ...Table of Contents 8 7750 SR a4 and SR a8 Installation Guide...
Page 12: ...List of Tables 12 7750 SR a4 and SR a8 Installation Guide...
Page 16: ...List of Figures 16 7750 SR a4 and SR a8 Installation Guide...
Page 22: ...Technical Support 22 7750 SR a4 and SR a8 Installation Guide...
Page 70: ...Safety Standards Compliance Agency Certifications 70 7750 SR a4 and SR a8 Installation Guide...
Page 136: ...Troubleshooting Initial Startup 136 7750 SR a4 and SR a8 Installation Guide...
Page 170: ...44 port 1GigE CSFP SFP MDA a Overview 170 7750 SR a4 and SR a8 Installation Guide...
Page 210: ...Removing and Replacing an Impedance Panel 210 7750 SR a4 and SR a8 Installation Guide...
Page 232: ...2015 Alcatel Lucent All rights reserved 3HE 10231 AAAA TQZZA Edition 01...