System Specifications
50
7750 SR-a4 and SR-a8 Installation Guide
1.
Height equals 7 RU.
2.
Width includes the integrated flanges for rack mounting.
3.
Depth does not include panel protrusions, such as panel screws, connectors, and ground studs.
Environmental Specifications
IOM-a slots
2
MDA-a slots
8
PSU slot
4
Fan tray slot
1
Air filter slot
1
Mounting
Mount in a recommended 19-in. (482.6 mm) equipment rack
Chassis has integrated mounting flanges for mounting in a 19-in.
(482.6 mm) rack.
Table 14: 7750 SR-a8 Chassis Specifications (Continued)
Parameter
Description
Table 15: 7750 SR-a4 Environmental Specifications
Parameter
Description
Normal operating temperature
23 to 113ºF (–5 to 45ºC)
Short-term operating temperature
23 to 131ºF (–5 to 55ºC)
Maximum altitude
13 000 ft (3962.4 m)
Normal operating relative humidity
5 to 90% (non-condensing)
Short-term operating relative humidity
5 to 93% (non-condensing)
Acoustic noise level
78 dBA at 27ºC (80.6ºF). Fan speed is adaptive.
Shock and vibration
Very low levels for continuous duration disturbance (similar
to modern office building, for example)
Shock: 3 g half sine 11 ms
Vibration: 0.1 g from 5 to 100 Hz
Summary of Contents for 7750 SR-a4
Page 8: ...Table of Contents 8 7750 SR a4 and SR a8 Installation Guide...
Page 12: ...List of Tables 12 7750 SR a4 and SR a8 Installation Guide...
Page 16: ...List of Figures 16 7750 SR a4 and SR a8 Installation Guide...
Page 22: ...Technical Support 22 7750 SR a4 and SR a8 Installation Guide...
Page 70: ...Safety Standards Compliance Agency Certifications 70 7750 SR a4 and SR a8 Installation Guide...
Page 136: ...Troubleshooting Initial Startup 136 7750 SR a4 and SR a8 Installation Guide...
Page 170: ...44 port 1GigE CSFP SFP MDA a Overview 170 7750 SR a4 and SR a8 Installation Guide...
Page 210: ...Removing and Replacing an Impedance Panel 210 7750 SR a4 and SR a8 Installation Guide...
Page 232: ...2015 Alcatel Lucent All rights reserved 3HE 10231 AAAA TQZZA Edition 01...