Installing Components
7750 SR-a4 and SR-a8 Installation Guide
121
Fiber Cables
Fiber-optic cables are routed in a similar fashion to Ethernet and copper wire cables. Cables
are routed to the left or right of the chassis.
Hardware required:
•
Velcro straps (optional)
To attach fiber cables:
Step 1.
Attach the cable to the port connector or SFP connector on the adapter card.
Step 2.
Route the cables to the left or right of the chassis. If needed, use a Velcro strap to
bundle the cables from each card.
Step 3.
Attach the fiber cable to a distribution panel or appropriate connector.
Alarm Port Connections
The Alarm port on the CPM-a has a 15-pin DB connector. Use a shielded cable to connect
the Alarm port to a suitable alarm panel, such as a punch-down or wire-wrap panel. See
Alarms Interface Port Pinouts on page 218
for the required pinout information.
To connect the Alarm port:
Step 1.
Connect the cable assembly to the External Alarm port.
Step 2.
Route the cable to the left or the right of the chassis.
Step 3.
Connect the far end of the cable to the alarm panel.
Warning:
•
Fiber cables are sensitive to bending, twisting and pulling. Extreme caution is
recommended when handling fiber cable.
•
To ensure that the minimum fiber bend radius is maintained in the allowable space
AT&T TP-76450 specifies a minimum of 1.0 in (25.4 mm) inside radius for single fibers.
•
Use fiber cable with a pre-installed open-angled 90º boot.
•
Observe correct fiber connector handling regarding the use of dust covers and cleaning.
Summary of Contents for 7750 SR-a4
Page 8: ...Table of Contents 8 7750 SR a4 and SR a8 Installation Guide...
Page 12: ...List of Tables 12 7750 SR a4 and SR a8 Installation Guide...
Page 16: ...List of Figures 16 7750 SR a4 and SR a8 Installation Guide...
Page 22: ...Technical Support 22 7750 SR a4 and SR a8 Installation Guide...
Page 70: ...Safety Standards Compliance Agency Certifications 70 7750 SR a4 and SR a8 Installation Guide...
Page 136: ...Troubleshooting Initial Startup 136 7750 SR a4 and SR a8 Installation Guide...
Page 170: ...44 port 1GigE CSFP SFP MDA a Overview 170 7750 SR a4 and SR a8 Installation Guide...
Page 210: ...Removing and Replacing an Impedance Panel 210 7750 SR a4 and SR a8 Installation Guide...
Page 232: ...2015 Alcatel Lucent All rights reserved 3HE 10231 AAAA TQZZA Edition 01...