Powering Up the 7750 SR-a
126
7750 SR-a4 and SR-a8 Installation Guide
Powering Up the 7750 SR-a
The 7750 SR-a4 and 7750 SR-a8 do not have a power switch or internal circuit breaker to turn
the power ON or OFF:
•
For AC power, power is supplied from an AC power outlet.
•
For –48 VDC power, the 7750 SR-a system DC power is supplied by a DC branch
circuit.
Power-Up
To power-up an AC powered system:
Danger:
•
You must comply with the general safety precautions and product requirements
described in
and the requirements described in
before performing the procedures contained in this chapter.
•
Do not power up a 7750 SR-a before verifying that all common equipment (chassis,
power, cooling, and grounding) is connected correctly.
•
Always keep your fingers away from rotating fan blades. Do not put your fingers or any
tool in the fan tray if the fans are still spinning.
Warning:
For correct thermal operation, ensure that Impedance panels are installed in all
empty slots before powering up the 7750 SR-a.
Note:
•
You must complete the procedure
Installing, Wiring, and Connecting an AC PSU on
(for systems using an AC power source) or
Installing, Wiring, and Connecting
(for systems using a DC power source), and the procedures
in
Installing Components on page 107
before proceeding with the power-up and
initialization procedure.
•
The primary copy of the 7750 SR-a TiMOS software is located on the compact flash
memory card that must be installed on the CPM, as described in
CF Card on the CPM-a on page 111
.
•
At power up, the fans initially run at full speed. Thereafter, the control system reduces
the fan speed based on temperature. During normal operation, fans never turn off
completely.
Summary of Contents for 7750 SR-a4
Page 8: ...Table of Contents 8 7750 SR a4 and SR a8 Installation Guide...
Page 12: ...List of Tables 12 7750 SR a4 and SR a8 Installation Guide...
Page 16: ...List of Figures 16 7750 SR a4 and SR a8 Installation Guide...
Page 22: ...Technical Support 22 7750 SR a4 and SR a8 Installation Guide...
Page 70: ...Safety Standards Compliance Agency Certifications 70 7750 SR a4 and SR a8 Installation Guide...
Page 136: ...Troubleshooting Initial Startup 136 7750 SR a4 and SR a8 Installation Guide...
Page 170: ...44 port 1GigE CSFP SFP MDA a Overview 170 7750 SR a4 and SR a8 Installation Guide...
Page 210: ...Removing and Replacing an Impedance Panel 210 7750 SR a4 and SR a8 Installation Guide...
Page 232: ...2015 Alcatel Lucent All rights reserved 3HE 10231 AAAA TQZZA Edition 01...