24
Optical Fusion Splicer Instruction Manual
6. Splicing Operation
6.1 Choose Splice Mode, Edit Splice Parameters
a.
Splice mode description
Splice Mode
Description
Fiber Type
SM (single mode), MM (multi-mode), DS
(dispersion), NZDS (non-zero dispersion),
BIF/UBIF EDF etc., Factory defined multi
default groups, user can choose different
splicing program with fiber type.
Splice method Automatic, semi-automatic and manual.
Splice Mode
No.
Current splice mode and
Edit splice
Program
Edit the current item’s splice parameters, as
Fig6.1.1.
Cleaning
ARC Time
Clear ARC is cleaning the dust on optical fiber
surface by ARC. The clean time range:
0-200ms
End-face
Angle Limit
Set the end face angle limit value, while the
right/left fiber exceed the set value, an error
prompt will show. Set range 0~8
°
.
Cleave angle
limit
Inclined angle limit after fiber align, if exceed
limitation, the error prompt will show, range
0~4
°
.
Fiber Align
Limit
After fiber align, if central deviation exceed
limitation, an error prompt will show, set
range: 0.0~1.5
µ
m.
Loss Limit
Estimated splice loss exceed limitation, an
error prompt will show, set range:0~0.2dB.