34
Optical Fusion Splicer Instruction Manual
Note:
Use the pre-set heat parameters, if the sleeve type is
“Blank”, system will auto-set the heating No. to “1”.
After changing electrodes, updated program, user must do
shrink calibration to avoid influencing shrink result.
a.
Open up the cover of heater.
b.
Open the wind protector cover, take out spliced fiber and more
the sleeve to the center of spliced spot.
c.
Placed the fiber into heating stove, slightly pull the fiber to be
straight and keep the sleeve in the center of heating stove,
then close the heater cover.
d.
Choose heating mode, and confirm heating parameters (If
same with previous heating, ignore this step).
e.
Press
to start heat, the indicator light will turn on in
red, if press
during heating, then heating will cancel.
f.
After heating, the indicator light will extinguish. Open the
heater cover and take out the heated sleeve. (Note: do not
touch the heated sleeve to avoid scald)
g.
Check the shrink result, if it is qualitied, place the sleeve into
cool tray to wait for natural cooling, otherwise, such as dust or
bubbles inner sleeve, do heating operation again until its
qualified.