Optical Fusion Splicer Instruction Manual
Fig 6.1.1 Edit Splice Mode Menu
Manual ReARC
Time
Set the ReARC time. With some situation,
splice loss can be reduced by ReARC.
Align Type
Set Refined, clad and Core alignment, default
core alignment.
Quick Splice
Mode
Can be set On/off, if open, splice time will at
min. 7 sec.
Forced Splice
Mode
When aligning the fiber, if the fiber can’t
calibrate normally, such as cleave end face
isn’t meet the align need, user can choose this
mode to splice forcedly. Note: this operation
will increase the splice loss, so it is just suit for
some special circumstances.
b.
Under “Splice Mode” Menu, choose “Edit Splice Program” to edit
the splice parameters. As Fig 6.1.1.