![AiP ABL-005IR Manual Download Page 8](http://html.mh-extra.com/html/aip/abl-005ir/abl-005ir_manual_2872213008.webp)
SWIR Line Camera Series User’s Manual
(OM150000013H-EN)
-
8
-
2.
Product Overview
This product is SWIR camera equipped with InGaAs line
sensor.
2-1
Features
Short Wave Infrared Sensitivity
ABL-005IR
The sensor has 512pixels, and its spectral
response range is 950nm~1700nm.
ABL-005MIR
The sensor has 512pixels, and its spectral
response range is 1100nm~1900nm.
ABL-005WIR
The sensor has 512pixels, and its spectral
response range is 900nm ~ 2550nm.
ABL-010IR
The sensor has 1024pixels, and its spectral range
is 950nm ~ 1700nm.
Interface
User can choose one of the followings.
[Gigabit Ethernet(1000BASE-T)]
ABL-005IR-GE / ABL-005MIR-GE
ABL-005WIR-GE / ABL-010IR-GE
Gig.E Vision Interface for ease of use inPC.
GenICam is supported.
[CameraLink]
ABL-005IR-CL / ABL-005MIR-CL / ABL-010IR-CL
CameraLink base configuration is supported.
This interface is preferred for the application
requiring a faster rate and reliability.
Various Functions
Following functions are provided in this product and
simply programmed by sending a command.
・
Gain
・
Exposure Control
・
LUT
(
Look Up Table)
・
Output Bit
:
8/10/12Bit
・
Defect pixel Correction
・
Shading Correction
Exposure Control
Exposure control is available in between 10μs and
1ms by in a unit of 1μs
External Trigger for Exposure Control
User can control exposure timing synchronizing with
an external trigger signal.
Camera Mounting
The camera has mounting holes on top and bottom of
the housing.
LUT
(
Look Up Table
)
User can select whether to use LUT function or not by
set On/Off. For the details of how to program LUT,
please refer to section
Output Bit
User can configure the camera to output image data
8, 10, 12 and 14bit.
Defect Pixel Correction
Defect pixel can be compensated by defect pixel
correction function. If you want to use this function,
you can activate it by set On/Off.
Shading Correction
Shading image generally caused from the lighting or
lens can be corrected by shading correction function.
If you want to use this function, you can activate it by
set On/Off.
SFNC Standard
Except for the few, all the functionalities
‘
name
described in this manual are used conforming to the
GenICam SFNC(Standard Feature Naming
Convention).
NOTE
It is applicable to Gig.E version camera only.
※
For the details of GenICam GenTL, SFNC
Standard, etc., visit following website.