ABL-010IR Data Output Timing
ABL-010IR has different timing to start data output to ABL-005IR/ABL-005MIR/ABL-005WIR.
Time to start data readout
In general, SWIR line camera output data after exposure is completed.
However, ABL-010IR outputs previous data when exposure starts.
In case of using ABL-010IR, the first line should be removed and consider to take one additional line.
Propagation Delay(T
PD
)
ABL-010IR
:
44.04us
ABL-010IR
IR
N+1
T
PD
N
Integration
Readout
N
N+1
N+2
Propagation Delay(T
PD
)
ABL-005IR
:
127.86us
ABL-005IR
N+1
N+2
T
PD
N
Integration
Readout
N
N+1