![AiP ABL-005IR Manual Download Page 36](http://html.mh-extra.com/html/aip/abl-005ir/abl-005ir_manual_2872213036.webp)
SWIR Line Camera Series User’s Manual
(OM150000013H-EN)
-
36
-
4-13-3
Line Start & Timed Mode
In case Line Start trigger is enabled, the camera outputs 1 frame captured during the time valid trigger condition.
・
Line Start
Trigger for indicating valid exposure time
In case of Timed mode, Exposure time needs to be set with
「
exposure/exp
」「
ExposureTime
」
.
In this mode, line rate setting programmed in
「
linerate
」「
AcquisitionLineRate
」
is ignored.
NOTE
ABL-005MIR has the same specification of ABL-005IR.
Setting(Line Start)
command
param1
Description
CL
exp-mode
0
ExposureMode
trg-selector
9
LineStart
trg-source
64
CC1
trg-mode
1
trg-activation
3
trg-delay
0
GV
ExposureMode
Timed
TriggerSelector
LineStart
TriggerSource
Line0
TriggerMode
On
TriggerActivation
LevelHigh
TriggerDelay
0
us