60
-
5-6
Setting Range and Limitation
Name
Command
Recommended Range
Threshold
Unit
Min.
Max.
Min.
Max.
Output Bit
※
1
CL : pixel-depth
bit
GV : PixelFormat
8
12
8
14
bit
Exposure Time
CL : exposure
exp
GV : ExposureTime
10
1,000
10
100,000
μs
Digital
Offset
Gain
CL : gain
GV : Gain
0
12
-31.99 x
31.99 x
dB
Sensor Temp.
※
3
GV:
DeviceTemperatureTarget
※
2
※
2
-30
60
℃
※
1 In fact, Max. resolution is 13.5bit, so 14bit setting is not recommended.
※
2 Thermoelectric cooler has limitation to set the temperature as below.
・
In case the temperature is set to 60
℃
, sensor’s temperature inside of the housing is lower than 60
℃
.
・
In case of difference between the programmed temperature and ambient temperature is higher than 20
℃
,
sensor’s temperature inside of the housing is higher than programmed temperature.
※
3 ABL-005WIR is supported only to set sensor temperature setting.
5-7
Line Rate & Exposure Time
The camera takes specific time to read out sensor’s data time as shown below.
So,
『
Exposure Time
+
Data Output Time
』
needs to be set shorter than line rate.
露光時間+データ出力時間<ラインレート時間
Exposure Time
Sensor Output Time
In case sending Exposure command to set
『
Exposure Time
+
Data Output Time
』
longer than line rate, line rate is adjusted
automatically.
In case sending Linerate command to set line rate shorter than
『
Exposure Time
+
Data Output Time
』
, exposure time
adjusted automatically.
■
Sensor Readout Time
Camera
Sensor Readout Time[us]
ABL-005IR/ABL-005MIR
113
ABL-005WIR
62
ABL-010IR
5
The max. line rate can be configured as shown below at min. exposure time.
■
Sensor output time
Camera
Line Rate[Hz]
Exposure Time[us]
ABL-005IR/ABL-005MIR
8130
10
ABL-005WIR
13888
10
ABL-010IR
40000
10
Exposure
Time
Sensor read out
Time
Line Rate