![AiP ABL-005IR Manual Download Page 43](http://html.mh-extra.com/html/aip/abl-005ir/abl-005ir_manual_2872213043.webp)
SWIR Line Camera Series User’s Manual
(OM150000013H-EN)
-
43
-
4-14-1
Line 0,1,2 (CC1~4)
Line0 and Line1 are as two-way signal accessible in GPIO
circuit. Line2 is accessible in GPI cicuit only.
details.
In case of CameraLink version camera, additional input
signal can be assigned with CC1~CC4.
※
CC1
~
CC4 is for input only.
Following is command list to change source of Line* signal.
NOTE
ABL-010IR-CL is not supported.
ABL-010IR-GE is supporting GPI only.
command
param1
Description
CL
line-format
0
No Connect
4
EIA-422 Level
※
7
EIA-422 Level
without Input terminating
resitances
GV
LineFormat
NoConnect
No Connect
TTL
VHI : +2.0V
~
+5.0V
VIL : +0V
~
+0.8V
RS422
EIA-422 Level
※
RS422
without
terminal
EIA-422 Level
without Input terminating
resitances
※
In case selected EIA-422 level and set LineMode to Input,
it is connected to On Chip Termination automatically.
Following is command to change input direction of Line*
signal.
command
param1
Description
CL
line-mode
0
Input
1
Output
GV
LineMode
Input
Input
Output
Output
Followng is command to acquire current signal’s level.
command
param1
Description
CL
line-status
0
Negate
1
Assert
GV
LineStatus
Off
Negate
On
Assert
Following is command to reverse the level of Negate or
Assert.
command
param1
Description
CL
line-inverter
0
Non inverted
1
Inverted
GV
LineInverter
Off
Non inverted
On
Inverted
4-14-2
Line 0,1,3~6 Output
Line 0,1,3~6 can be connected to the signal output from
Acquisition Control or the signal from
「
UserOutput
」
.
NOTE
ABL-010IR-CL is not supported.
User can select the signal to connect to by following
command.
command
param1
Description
CL
line-source
0
AcquisitionTriggerWait
4
AcquisitionActive
14
ExposureActive
33
UserOutput0
35
UserOutput1
255
OFF
GV
LineSource
Off
AcquisitionTriggerWait
AcquisitionActive
ExposureActive
UserOutput0
UserOutput1
UserOutput2
※
1
UserOutput3
※
1
UserOutput4
※
1
UserOutput5
※
1
UserOutput6
※
1
NOTE
※
1
ABL-010IR-GE is supported only.
※
In case TriggerMode of Acquisition_** is set to 1, Acquisition
Trigger Wait is asserted until trigger is input.
To
Line Inverter
Acquisition Trigger Wait
※
Acquisition Active
Exposure Active
User Output0
User Output1
User Output2
OFF
Line Source
SEL
assert
negate