![AiP ABL-005IR Manual Download Page 41](http://html.mh-extra.com/html/aip/abl-005ir/abl-005ir_manual_2872213041.webp)
SWIR Line Camera Series User’s Manual
(OM150000013H-EN)
-
41
-
Timing
Power Connector 2-3Pin
Power Connector 5-4Pin
GPI0 Signal
GPI1 Signal
Line0
Line1
Encoder Circuit Sampling
Clock (6.25MHz)
PhaseA
PhaseB
Up Count Trigger
Down Count Trigger
Counter
Divider(value=1)
Encoder Trigger
Up Count Trigger
Down Count Trigger
Counter
Divider(value=3)
Encoder Trigger
Encoder Trigger
Line Active
Exposure Active
Sensor Exposure
Sensor Readout
Image Processing
Output
(CL Transmitter Input)
0
1
0
0
1
(4 States mode)
(High Resolution Mode)
0
1
2
3
4
5
6
5
4
3
2
0
1
2
2.14us
180ns
320ns
640ns
Tortal: 3.28us
typ 50ns max 70ns
Digital Noise Filter Setting(us)+80ns
0.04us
8.712us
005IR
:
105.86us 005WIR
:
54.9us
20.48us
22us
Total 005IR
:
127.86us 005WIR
:
77.3us
005IR
:
104.3us 005WIR
:
53.14us
0.14us+TriggerDelay
Exposure
※
Exposure CL
:
exposure(exp) command setting
GV
:
ExposureTime