![AiP ABL-005IR Manual Download Page 32](http://html.mh-extra.com/html/aip/abl-005ir/abl-005ir_manual_2872213032.webp)
SWIR Line Camera Series User’s Manual
(OM150000013H-EN)
-
32
-
4-13
Trigger Setting and Timing
4-13-1
Timed Mode(Free run)
This is the mode to start acquisition without SW or external trigger and acquire image data sequentially according to the
setting such as exposure time. Control signal for LVAL, FVAL is generated within the camera.
In Timed(a.k.a free run) mode, exposure time and frame rate can be programmed, but acquisition timing cannot be
controlled.
NOTE
ABL-005MIR has the same spec of ABL-005IR.
Setting
command
param1
Features
CL
exp-mode
0
ExposureMode
trg-selector
0
AcquisitionStart
trg-mode
0
trg-selector
1
AcquisitionEnd
trg-mode
0
trg-selector
2
AcquisitionActive
trg-mode
0
trg-selector
9
LineStart
trg-mode
0
GV
ExposureMode
Timed
TriggerSelector
AcquisitionStart
TriggerMode
Off
TriggerSelector
AcquisitionEnd
TriggerMode
Off
TriggerSelector
AcquisitionActive
TriggerMode
Off
TriggerSelector
LineStart
TriggerMode
Off
Timing
ABL-005IR
Scan Rate
※
Exposure
※
Exposure Active
Sensor Exposure
Sensor Readout
Image Processing
Output
(CL Transmitter Input)
FrameRate CL
:
1/scan rate(scan) command Setting
GV
:
1/Acquisition Frame Rate
Exposure CL
:
exposure(exp) command Setting
GV
:
ExposureTime
8.712us
005IR
:
105.86us
005WIR
:
54.9us
20.48us
22us
Total
005IR
:
127.86us
005WIR
:
77.3us