- 19 -
If the connection to the controller (process controls) via wireless
connection through an access point is interrupted and a job has
already been released in the tool, it should be further processed
if possible. After completing the job, the tool will try to send the
fastening process results. If the connection to the process controls
cannot be restored, the fastening process results must be manually
secured (read out of the tool using the AcraDyne Tool Manager
software and saved).
Then, after removing the battery, the back-up strategy can be used
to continue working.
To do this, hold down the trigger and slide the battery back on. After
approx. 3 seconds, the set-up symbol will appear on the display. You
can now release the trigger and will be in the set-up menu.
By pressing the menu button, you can go to the next menu point.
By pressing the trigger, you can select a menu point. Using the left
button, confirm your selection; with the right button, cancel the
selection.
To activate the back-up strategy, the "Set-up" menu
must be activated in the software under the general
settings. Also activate "scanner selectable" so the set-
up menu point "Scanner" can be selected. If you also
activate "Manual mode selectable," the set-up menu
points "M" and "Scanner M" will be released. So you can
select different programs per display, the check mark
next to "Manual mode active" must also be selected.
4.4.0. BACK-UP STRATEGY
Menu Button
Go to the next menu point
Confirm the
entry / selection
Cancel/decline the
entry / selection