Auto Width Adjust Conveyor Setup
6
Agilent U1840A Medalist sj5000 Hardware Manual
6-5
the clamp assembly up by hand so the edges meet, making
sure the clamps are parallel to each other.
7
Tighten all the machine screws along the finger clamp.
8
Re-check the full edge clearance by measuring the distance
from the inside of the linear rail to the outside edge of the
clamp.
9
Ensure that all clamps are straight, parallel and free moving.
The distance must not exceed 4.75 mm (SMEMA). (This
distance is set to 3.5 mm when the sj5000 is manufactured.)
Outer edge of finger
clamp against outer
edge of clamp blade
3.5 mm
Belt
Clamp