6-12
Agilent U1840A Medalist sj5000 Hardware Manual
6
Auto Width Adjust Conveyor Setup
General Conveyor Checks
In order to check the clamps, stops and sensors, access to the
interior of the machine is required. The
MAINT. SWITCH
is used
to enable Maintenance mode for such checks. In Maintenance
mode, no power or control is given to the gantry or conveyor
belt motors, to safeguard personnel carrying out maintenance
and calibration on the system.
1
Remove any boards from the conveyor, and make sure the
sj5000 software is running.
2
Turn the
MAINT. SWITCH
clockwise to the ON position and
push the E-Stop button (the sequence is not important).
3
Open the front access door.
4
In Maintenance mode, use the
Up
and
Down
buttons in the
software to control the movement of the clamps and stops.
Summary of Contents for U1840A Medalist sj5000