10-10
Agilent U1840A Medalist sj5000 Hardware Manual
10
Setting Up Barcode Readers
Microscan MS-820 Serial Barcode Reader
•
•
Set Up Single Barcode Reader
Plug the serial cable (p/n 5186-4835) into the XP-40 port on the
breakout box as shown below, and plug other end into the
MS-820 barcode reader.
Plug the trigger cable into the XS-42 port on the breakout box.
Program the Barcode Reader
Install the software as described in
and do the following:
1
Start the ESP software.
2
Select
MS-820
in the Select a model dialog box and click
OK
.
3
When prompted to connect to the barcode reader, click
Yes
.
4
Ensure COM port 4 is selected and click
Start
.
5
Click
App Mode
.
6
Click
File
>
Open
to open the setup file Single 820.esp.
7
Click
Send/Recv
>
Send to Reader
>
Send and Save
.