Agilent Technologies G8600-68001 Field Installation Instructions Download Page 19

                                                                                        

Page 

3

 of 

3

                                                  

  

Vacuum Products Division 

 

Request for Return Form 

 

Customer information 

Company : 

Contact Name: 

Address: Tel: 

Fax: 

 Email: 

 

Equipment 

Product description 

Agilent PartNo 

Agilent Serial No 

Original Purchasing Reference 

 

 

 

 

Failure description  

 

 

Type of process 

(for which the equipment was used) 

 

 

Type of return 

 

 Non Billable

    

Billable    

        New PO # (hard copy must be submitted with this form):  ______________________________________

 

 

 

Exchange        Repair       Upgrade     Consignment/Demo      Calibration      Evaluation      

 

Return for Credit

 

 

Health and safety

 

The product has been exposed to the following substances: 

(by selecting ‘YES’ you MUST complete the table to the right) 

Substances 

(please refer to MSDS forms)  

*

 Agilent will not accept delivery of any product that is exposed to radioactive, biological, 

explosive substances or dioxins, PCB’s without written evidence of decontamination.

 

Trade name

 

Chemical name 

Chemical Symbol 

CAS Number 

Toxic 

 YES    

 NO 

 

 

 

 

Harmful 

 YES    

 NO 

 

 

 

 

Corrosive 

 YES    

 NO 

 

 

 

 

Reactive 

 YES    

 NO 

 

 

 

 

Flammable 

 YES    

 NO 

 

 

 

 

Explosive (*) 

 YES    

 NO 

 

 

 

 

Radioactive (*) 

 YES    

 NO 

 

 

 

 

Biological (*) 

 YES    

 NO 

 

 

 

 

Oxidizing 

 YES    

 NO 

 

 

 

 

Sensitizer 

 YES    

 NO 

 

 

 

 

Other dangerous substances  

 YES    

 NO 

 

 

 

 

Goods preparation 

If you have replied YES to one of the above questions. Has the product been purged?   

 YES    

 NO

    

If yes, which cleaning agent/method: 
Has the product been drained from oil? 

  

 YES    

 NOT APPLICABLE

     

I confirm to place this declaration on the outside of the shipping box. 

 

   

 

I declare that the above information is true and complete to the best of my knowledge and belief. 

I understand and agree to the terms and conditions on page 2 of this document.

 

Name: 

Authorized Signature: 

Position: 
Date: 

NOTE

: If a product is received at Agilent which is contaminated with a toxic or hazardous material that was not disclosed, 

the customer will be held 

responsible

 for all costs incurred to ensure the safe handling of the product, and is liable for any harm or injury to Agilent employees as well as to any third 

party occurring as a result of exposure to toxic or hazardous materials present in the product.

 

 

 

Summary of Contents for G8600-68001

Page 1: ...Vacuum Products Division Wireless Remote Base Unit for VS Series and G8610 G8611 or G8612 Series Leak Detectors G8600 68001 Part Number 699910002 Rev D August 2017 FIELD INSTALLATION INSTRUCTIONS ...

Page 2: ...Wireless Remote Base Unit for VS Series and G8610 G8611 or G8612 Series Leak Detectors This page intentionally left blank ...

Page 3: ...ION Cautions appear before instructions which if not followed could cause damage to the equipment or data loss WARNING Warnings appear for a particular procedure or practice which if not followed correctly could lead to serious injury or death Hazard and Safety Information The common international symbols used in this manual and on the equipment are defined below O OFF Supply Power Earth Ground Te...

Page 4: ...arding specific requirements and regulations Address any safety operation and or maintenance questions to your nearest Agilent office NOTE To clean the leak detector plastic enclosure the LCD display and Front Panel buttons use only a soft cloth slightly dampened with water or a mild soap Do NOT use excess water or cleaning solvents of any kind Avoid splashing any liquids into the unit through the...

Page 5: ...e Wrench Antenna M3 Screw Qty 4 Installation Procedure For clarity some items have been omitted from views Figure 1 Rear and Front Cover Screws WARNING Disconnect power from the unit before performing any maintenance procedure that requires physically disconnecting any part of the system NOTE Prior to wireless PCB installation ensure that the software is revision 4 02 or higher by navigating from ...

Page 6: ... holding the front plastic cover and detach the cover from the unit Two screws are situated at the front of the unit not shown and two screws are positioned inside the unit Figure 1 Rear and Front Cover Screws Figure 2 Fan Assembly and Socket Head Cap Screw 5 Disconnect the fan connector from the 24 V cable harness 6 Detach the fan assembly by removing the M4 socket head cap screw and loosening th...

Page 7: ...es and G8610 G8611 or G8612 Series Leak Detectors Page 5 of 14 Document No 699910002 Revision D Figure 4 Base Board Assembly with Posts Figure 5 Antenna Connector CAUTION Use proper ESD safety techniques when performing a PCB card install ...

Page 8: ...he connector is firmly seated in the jack 10 Secure the wireless base board to the fan bracket using the four M3 Phillips screws provided with the kit 11 Unfurl the black red wire P1 RF with the 24 V three pin connector and the ground lug Figure 6 24 V Power Cable which is tie rapped at the base of the leak detector and Plug the 24 V connector labeled P1 RF into the three pin connector on the wire...

Page 9: ... M6 screw and washer from the front panel display and detach the display Figure 7 Front Panel Display 15 Connect the RS 232 cable end labeled J300 2 to P300 COM2 on the front panel display board using its two slotted screws Figure 8 RS232 Cable Figure 8 RS232 Cable 16 Reattach the display by inserting the tabs into their slotted positions and secure using the M6 screw and washer 17 Attach the fron...

Page 10: ...ure 9 Label 21 Connect the power cord and power up the unit 22 Watch the home screen to verify the Spectube Pressure Wait message progresses to Stabilization Wait and System Ready within ten minutes Refer to the operator s manual if the system fails to reach the System Ready mode 23 After installation refer to the VS Series leak detector manual P N 699909942 Section 3 for leak detector activation ...

Page 11: ...ty 4 Installation Procedure For clarity some items have been omitted from views WARNING Disconnect power from the unit before performing any maintenance procedure that requires physically disconnecting any part of the system 1 Turn off the power switch located on the back of the unit and unplug 2 Wait 30 seconds for the high voltage to dissipate Figure 1 Orientation 3 Using slotted screw driver un...

Page 12: ...will be installed Figure 2 Lid Figure 2 Removing Valve 5 If the leak detector configuration has a valve in front of the bottom left post move that valve aside by unscrewing the two screws circled Figure 2 Removing valve Keeping the wiring connected set valve aside This valve is only used on certain models of leak detectors If the valve is not present ignore this step PCB to mount to opposite side ...

Page 13: ...r posts noting the correct orientation Fasten with screws Figure 3 Base Board Assembly with Posts Figure 3 Base Board Assembly with Posts 7 Using the provided washer and nut hand tighten the antenna to the outside of the leak detector wall and then apply a turn using an adjustable wrench Figure 4 Wireless Antenna Figure 4 Wireless Antenna O ring on Outside Not Shown Washer Nut ...

Page 14: ...refully center the connector on the jack and press the connector onto the jack until it snaps into place Rotate the antenna cable to ensure the connector is firmly seated in the jack 9 Connect the RS 232 on the wireless board using its two slotted screws Figure 6 RS232 Connection left side Plug in the other side of the ribbon cable to the green port on the CPU board located on the front side of th...

Page 15: ...ector labeled P1 RF into the three pin connector on the wireless board Attach the 24 V ground lug to one of the bracket screws Figure 7 24 V Power Cable 11 Reinstall the valve and dress internal wires inside of leak detector Figure 2 Removing Valve 12 Reattach front and side Figure 1 Covers 13 Rotate the antenna to its horizontal locked position 14 Guide the antenna through its location hole in th...

Page 16: ... cord and power up the unit 17 Watch the home screen to verify the Spectube Pressure Wait message progresses to Stabilization Wait and System Ready within ten minutes Refer to the operator s manual if the system fails to reach the System Ready mode 18 After installation refer to the Leak Detector manual section for leak detector activation of the wireless remote 19 Refer to the wireless remote use...

Page 17: ...m the core product e g inlet screens vent valves o Prior to shipment and if applicable for your product drain any oils or other liquids purge or flush all gasses and wipe off any excess residue o If ordering an Advance Exchange product please use the packaging from the Advance Exchange to return the defective product o Seal the product in a plastic bag and package product carefully to avoid damage...

Page 18: ... returning a non rebuildable part crashed will result in an invoice for the non returned non rebuildable part o Returns for credit toward the purchase of new or refurbished Products are subject to prior Agilent approval and may incur a restocking fee Please reference the original purchase order number o Units returned for evaluation will be evaluated and a quote for repair will be issued If you ch...

Page 19: ...r Toxic YES NO Harmful YES NO Corrosive YES NO Reactive YES NO Flammable YES NO Explosive YES NO Radioactive YES NO Biological YES NO Oxidizing YES NO Sensitizer YES NO Other dangerous substances YES NO Goods preparation If you have replied YES to one of the above questions Has the product been purged YES NO If yes which cleaning agent method Has the product been drained from oil YES NOT APPLICABL...

Page 20: ...apan Ltd 9 1 Takakura cho Hachioji city Tokyo Japan Tel 81 3 5232 1253 Fax 81 120 565 154 Toll Free 81 120 477 111 jp vvt sales pdl ext agilent com Korea Agilent Technologies Korea Ltd Ilshin Builiding 4F Yongsan gu Hannam daero Seoul Korea 04418 Tel 82 0 2 2194 9449 Fax 82 0 2 2194 9853 Toll free 080 222 2452 vpk customerservice agilent com Mexico Agilent Technologies Concepcion Beistegui No 109 ...

Reviews: