![Agilent Technologies FieldFox N9912A User Manual Download Page 94](http://html1.mh-extra.com/html/agilent-technologies/fieldfox-n9912a/fieldfox-n9912a_user-manual_2868113094.webp)
94
N9912A FieldFox User’s Guide
Then
More
.
Then
Marker Function
Then
Noise ON OFF
.
Band/Interval Power Marker
A Band/Interval Power marker, unique to SA Mode, accumulates the power that
is measured over several adjacent data points (or ‘buckets’). The range of buckets
being measured is displayed with vertical posts around the marker. This Band
Span value is selectable.
This feature is very similar to a channel power measurement (page 97).
When the frequency span is set to Zero span, the marker is referred to as an
Interval marker because it averages power over a specific time interval. In this
case the range is specified as the Interval Span. Learn more about Zero span
measurements on page 86.
If the Detection method and Averaging type are set to Auto when you enable a
Band/Interval Power marker, the Detection method will change to Average
(RMS) and Averaging type will change to Power average. Other Detection
methods or Averaging type settings will usually cause measurement inaccuracy.
Learn more about Detection method on page 91, and Averaging Type on page 90.
Summary:
In Zero span, an Interval Power Marker yields the
average power
over the
specified time interval.
In non-Zero span, a Band Power Marker yields the
total power
over the
specified frequency range.
How to measure Band/Interval Power with a marker
Press
Marker
to create or select a Normal or Delta marker to use to measure
Band/Interval Power.
Then press
More
Then
Marker Function
Then
Band/Int Power
Then
Band (or Interval) Span
Then choose from the following:
o
Auto
Measures power over 5% of the displayed span, or ½ graticules. The
Band Span is automatically updated to remain at 5% when you change the
frequency span.
o
Man
Enter a frequency or time value using the
▲|▼
arrows or the rotary
knob, then press
Enter
. Or enter a value using the numeric keypad and
select a frequency or time suffix. The Band Span remains at the frequency or
time value that you set as the span changes.
Summary of Contents for FieldFox N9912A
Page 15: ...Preparing for Initial Use of Your New FieldFox 15 Take the FieldFox Tour Front Panel ...
Page 194: ...194 N9912A FieldFox User s Guide Batteries Safe Handling and Disposal ...
Page 195: ...Safety Considerations 195 Inspired Energy Battery ...
Page 196: ...196 N9912A FieldFox User s Guide ...
Page 197: ...Safety Considerations 197 ...
Page 198: ...198 N9912A FieldFox User s Guide ...