![Agilent Technologies FieldFox N9912A User Manual Download Page 82](http://html1.mh-extra.com/html/agilent-technologies/fieldfox-n9912a/fieldfox-n9912a_user-manual_2868113082.webp)
82
N9912A FieldFox User’s Guide
Then
Mkr->Tune Freq
to change the Tune Frequency to that of the marker.
Tip
To improve sound quality, try increasing power by reducing the Attenuation
setting and, if available, turn ON the Preamplifier. Learn how on page 75.
Listen Time
While Tune & Listen is actively demodulating a signal, the SA does not sweep
and update the display. Listen Time sets the amount of time that the FieldFox
demodulates, then stops to perform a single sweep and update the display, then
again demodulates.
To select Listen Time:
Press
Meas Setup 4
Then
Listen Time
Enter a value using the numeric keypad,
▲|▼
arrows, or the rotary knob.
Then select a multiplier key. Learn about multiplier abbreviations on page 19.
Volume Control
To increase or decrease the Volume of the demodulated signal:
Press
Meas Setup 4
Then
Volume
Enter a value in percent between 0 and 100 (loudest) using the numeric
keypad,
▲|▼
arrows, or the rotary knob.
Volume can also be changed and easily muted from the
System
menu. Learn
more on page 160.
Demod ON and OFF
To quickly stop the audio demodulation and perform only the normal SA sweeps,
select the following:
Press
Meas Setup 4
Then
Demod ON OFF
Independent Source/Tracking Generator
A tracking generator, a popular option with Spectrum Analyzers, is a source
which always tracks the SA receiver.
Like a traditional tracking generator, the Independent Source feature can set the
internal FieldFox source to track the SA receiver frequency range. It can also set
the internal source to a CW frequency that is independent of the SA frequency.
Independent Source can be enabled ONLY when the FieldFox is in SA mode.
To view the internal source, you must connect a cable or device between the RF
OUT connector and the RF IN connector.
How to make Independent Source Settings
Press
Measure 1
.
Then
Source
Summary of Contents for FieldFox N9912A
Page 15: ...Preparing for Initial Use of Your New FieldFox 15 Take the FieldFox Tour Front Panel ...
Page 194: ...194 N9912A FieldFox User s Guide Batteries Safe Handling and Disposal ...
Page 195: ...Safety Considerations 195 Inspired Energy Battery ...
Page 196: ...196 N9912A FieldFox User s Guide ...
Page 197: ...Safety Considerations 197 ...
Page 198: ...198 N9912A FieldFox User s Guide ...