7
381
SCPI Command Reference
List by function
7. SCPI Command
Re
fe
re
nc
e
Frequency, RF
power and DC
current measurement
- Limit Test
(Continued)
Turns on/off the limit line
:DISP:FP[1-1]:TRAC[1-4]:LIM:LINE
Turns on/off the limit test judgement display
:DISP:FP[1-1]:LIM:FSIG
Reads the upper limit line
:MMEM:FP[1-1]:TRAC[1-4]:LOAD:LIM:UPP
Reads the lower limit line
:MMEM:FP[1-1]:TRAC[1-4]:LOAD:LIM:LOW
Frequency, RF
power and DC
current measurement
- Marker/analysis
Turns on/off bandmarker coupling function
:CALC:FP[1-1]:ALLT:BDM:X:COUP:STAT
Turns on/of marker coupling function
:CALC:FP[1-1]:ALLT:MARK:COUP:STAT
Sets/Reads marker movement (Continuous/Discrete)
:CALC:FP[1-1]:ALLT:MARK:DISC:STAT
Sets/Reads marker reference number
:CALC:FP[1-1]:ALLT:MARK:REF:NUMB
Turns on/off delta marker mode
:CALC:FP[1-1]:ALLT:MARK:REF:STAT
Selects active marker
:CALC:FP[1-1]:TRAC[1-4]:ALLM:ACT
Sets/Reads marker search range (X-axis)
:CALC:FP[1-1]:TRAC[1-4]:ALLM:SEAR:DOM:X
Sets/Reads marker search range (Y-axis)
:CALC:FP[1-1]:TRAC[1-4]:ALLM:SEAR:DOM:Y
Executes marker search all
:CALC:FP[1-1]:TRAC[1-4]:ALLM:SEAR:PEAK
Sets/Reads the center value of bandmarker X
:CALC:FP[1-1]:TRAC[1-4]:BDM:X:CENT
Sets/Reads the span value of bandmarker X
:CALC:FP[1-1]:TRAC[1-4]:BDM:X:SPAN
Sets/Reads the start value of bandmarker X
:CALC:FP[1-1]:TRAC[1-4]:BDM:X:STAR
Turns on/off bandmarker X
:CALC:FP[1-1]:TRAC[1-4]:BDM:X:STAT
Sets/Reads the stop value of bandmarker X
:CALC:FP[1-1]:TRAC[1-4]:BDM:X:STOP
Sets/Reads the center value of bandmarker Y
:CALC:FP[1-1]:TRAC[1-4]:BDM:Y:CENT
Sets/Reads the span value of bandmarker Y
:CALC:FP[1-1]:TRAC[1-4]:BDM:Y:SPAN
Sets/Reads the start value of bandmarker Y
:CALC:FP[1-1]:TRAC[1-4]:BDM:Y:STAR
Turns on/off bandmarker Y
:CALC:FP[1-1]:TRAC[1-4]:BDM:Y:STAT
Sets/Reads the stop value of bandmarker Y
:CALC:FP[1-1]:TRAC[1-4]:BDM:Y:STOP
Sets/Reads analysis/search range (X-axis)
:CALC:FP[1-1]:TRAC[1-4]:FUNC:DOM:X
Sets/Reads analysis/search range (Y-axis)
:CALC:FP[1-1]:TRAC[1-4]:FUNC:DOM:Y
Reads the results of statistical analysis for the data
trace
:CALC:FP[1-1]:TRAC[1-4]:FUNC:STAT:DATA
Reads the results of statistical analysis for the
memory trace
:CALC:FP[1-1]:TRAC[1-4]:FUNC:STAT:MEM
Sets/Reads analysis type
:CALC:FP[1-1]:TRAC[1-4]:FUNC:TYPE
Executes marker peak search left
:CALC:FP[1-1]:TRAC[1-4]:MARK[1-6]:SEAR:EXEC:L
PE
Executes marker target search left
:CALC:FP[1-1]:TRAC[1-4]:MARK[1-6]:SEAR:EXEC:L
TAR
Executes marker search maximum
:CALC:FP[1-1]:TRAC[1-4]:MARK[1-6]:SEAR:EXEC:
MAX
Function
Setting/Execution item
Command
Summary of Contents for E5052A
Page 4: ...4 ...
Page 28: ...28 1 Making Effective Use of This Manual How to Use This Manual ...
Page 51: ...3 51 Making a Measurement Trigger System 3 Making a Measurement Figure 3 1 Trigger system ...
Page 58: ...58 3 Making a Measurement Waiting for End of measurement ...
Page 76: ...76 4 Reading Writing Measurement Data Entering Data in a Trace ...
Page 82: ...82 Chapter5 Saving and Recalling File Management Managing Files ...