7
385
SCPI Command Reference
List by function
7. SCPI Command
Re
fe
re
nc
e
Phase noise
measurement - Limit
Test
Reads out the limit test result
:CALC:PN[1-1]:ALLT:LIM:FAIL
Turns on/off the limit test function
:CALC:PN[1-1]:TRAC[1-1]:LIM[:STAT]
Sets/Reads the number of segments in the upper limit
line
:CALC:PN[1-1]:TRAC[1-1]:LIM:UPP:SEGM:COUN
Sets/Reads the number of segments in the lower limit
line
:CALC:PN[1-1]:TRAC[1-1]:LIM:LOW:SEGM:COUN
Sets/Reads segment data of the upper limit line
:CALC:PN[1-1]:TRAC[1-1]:LIM:UPP:SEGM:DATA
Sets/Reads segment data of the lower limit line
:CALC:PN[1-1]:TRAC[1-1]:LIM:LOW:SEGM:DATA
Clears the upper limit line
:CALC:PN[1-1]:TRAC[1-1]:LIM:UPP:SEGM:CLE
Clears the lower limit line
:CALC:PN[1-1]:TRAC[1-1]:LIM:LOW:SEGM:CLE
Sets/Reads the upper limit values of all measurement
points
:CALC:PN[1-1]:TRAC[1-1]:LIM:UPP:LDAT
Sets/Reads the lower limit values of all measurement
points
:CALC:PN[1-1]:TRAC[1-1]:LIM:LOW:LDAT
Reads out the limit test result
:CALC:PN[1-1]:TRAC[1-1]:LIM:FAIL
Reads the limit test results of all measurement points
in selected traces
:CALC:PN[1-1]:TRAC[1-1]:LIM:REP[:DATA]
Turns on/off the limit line
:DISP:PN[1-1]:TRAC[1-1]:LIM:LINE
Turns on/off the limit test judgement display
:DISP:PN[1-1]:LIM:FSIG
Reads the upper limit line
:MMEM:PN[1-1]:TRAC[1-1]:LOAD:LIM:UPP
Reads the lower limit line
:MMEM:PN[1-1]:TRAC[1-1]:LOAD:LIM:LOW
Phase noise
measurement -
Marker/analysis
Turns on/off marker coupling function
:CALC:PN[1-1]:ALLT:MARK:COUP:STAT
Sets/Reads marker movement (Continuous/Discrete)
:CALC:PN[1-1]:ALLT:MARK:DISC:STAT
Sets/Reads marker reference number
:CALC:PN[1-1]:ALLT:MARK:REF:NUMB
Turns on/off delta marker mode
:CALC:PN[1-1]:ALLT:MARK:REF:STAT
Selects active marker
:CALC:PN[1-1]:TRAC[1-1]:ALLM:ACT
Sets/Reads marker search range (X-axis)
:CALC:PN[1-1]:TRAC[1-1]:ALLM:SEAR:DOM:X
Sets/Reads marker search range (Y-axis)
:CALC:PN[1-1]:TRAC[1-1]:ALLM:SEAR:DOM:Y
Executes marker search all
:CALC:PN[1-1]:TRAC[1-1]:ALLM:SEAR:PEAK
Sets/Reads the center value of bandmarker X
:CALC:PN[1-1]:TRAC[1-1]:BDM:X:CENT
Sets/Reads the span value of bandmarker X
:CALC:PN[1-1]:TRAC[1-1]:BDM:X:SPAN
Sets/Reads the start value of bandmarker X
:CALC:PN[1-1]:TRAC[1-1]:BDM:X:STAR
Turns on/off bandmarker X
:CALC:PN[1-1]:TRAC[1-1]:BDM:X:STAT
Sets/Reads the stop value of bandmarker X
:CALC:PN[1-1]:TRAC[1-1]:BDM:X:STOP
Sets/Reads the center value of bandmarker Y
:CALC:PN[1-1]:TRAC[1-1]:BDM:Y:CENT
Sets/Reads the span value of bandmarker Y
:CALC:PN[1-1]:TRAC[1-1]:BDM:Y:SPAN
Function
Setting/Execution item
Command
Summary of Contents for E5052A
Page 4: ...4 ...
Page 28: ...28 1 Making Effective Use of This Manual How to Use This Manual ...
Page 51: ...3 51 Making a Measurement Trigger System 3 Making a Measurement Figure 3 1 Trigger system ...
Page 58: ...58 3 Making a Measurement Waiting for End of measurement ...
Page 76: ...76 4 Reading Writing Measurement Data Entering Data in a Trace ...
Page 82: ...82 Chapter5 Saving and Recalling File Management Managing Files ...