READ:NTP_CHAN? <chan no.>
Query Normally Transmitted Power (NTP) in a specific channel
READ:PSEUDO:DELTA_F1?
Query Pseudo Delta F1 Average
Syntax:
READ:NTP_CHAN? <chan no.>
Value Range:
<chan no.>
<value>
Channel no. (0 to 78)
NTP for channel no. [dBm]
Default Value:
Not Applicable
Applicable in
State:
Query: CONN, TCONN, RFGE
Description:
This query is used to measure the Normally Transmitted Power
(NTP), average power, of the DUT for a specified channel. The test
set replies with the most recent NTP value for the specified
channel
If the NTP for this channel has not been previously measured
NAN is returned.
Example:
READ:NTP_CHAN? 40
Syntax:
READ:PSEUDO:DELTA_F1?
Value Range:
<value>
Deviation [kHz]
Default Value:
Not Applicable
Applicable in
State:
Query: TCONN, RFGE
Description:
This command initiates a pseudo delta F1 average measurement
of the DUT. This is achieved by searching for 111/000 patterns in
the access code part of the burst and using these to give an
indication of the Delta F1 value.
However, unlike the
DELTA_F1?
measurement, the
PSEUDO:DELTA_F1?
can be used with a normal connection
Example:
READ:PSEUDO:DELTA_F1?