Test Mode Page - Panel Summary
Panel
Parameters
Description
1.
Frequency Hop
Mode
Single Frequency or
Hopping Europe/ USA
Selects Frequency Hopping on or off
2.
Carrier
0 to 78
Entry and display of the ISM band channel
number (0 to 78, 2.402 to 2.480 GHz)
3.
Poll Period
1 to 255
Selects the time period for transmitting test
packets - depends on packet type
4.
Packet Types
DH1 to DH5, HV3 and
AUX1
Selects the data packet type
5.
Packet Length
1-27 for DH1
1-183 for DH3
1-339 for DH5
AUX1 (fixed)
HV3 (fixed)
Selects the packet length
6.
RF Level
-85 to 0dBm
Entry field or slider control
7.
Impairments
Mod. Index 0.28 to 0.35
Freq. Offset ±75kHz
Simulates poor transmitter performance.
8.
Meas. Averaging
Factor
1 to 999
Selects the number of packets to be used for the
measurement
9.
DUT Mode
Loopback or
Transmitter Test
Selects the test mode required for the DUT -
Loopback enables PER and BER measurements,
various modulation patterns can be used with
Transmitter Test
10. Modulation
Zero, One, BS55, BS0F,
SPSR, User Defined
Selects the modulation required for the
Transmitter Tests
11. DUT Power Control variable
Enables adjustment of DUT RF level (if
supported by DUT)
12. PER
Running Packet Error Rate
13. BER
1 to 1,600,000
Selects the required bits for the BER
measurement (Loopback test)
14. Page/Release
Opens and closes the Bluetooth connection to
the DUT