14
Parameters
Opens the first of two parameters screens. This button is password protected and should not be used
unless directed to make changes by Afinia Label Support.
Settings Screen
This screen is used to modify the operational settings of the
press.
Units
Set to either
Metric
(mm) or
Inch
. Pitch Length and Print
Speed values are converted when changing from one to the
other.
Label Pitch Length
Touch the small button to the right of the number to open the numeric keypad to enter in the label
pitch length. Measurements are from the top of one registration mark to the top of the next.
Print Speed
Enter the print speed in this field. You can also select the speed by touching the
6” / sec
or
12” / sec
buttons.
Infeed / Outfeed Speed
The Infeed and Outfeed speed settings can be changed, if necessary. It is not recommended that these
speeds be changed unless issues are occurring.
Registration On / Off
Toggles the Registration Sensor on or off. Turn registration off when cutting blank labels.
Loop Sensor On / Off
Toggles the loop sensor between on and off.
Manual Screen
Use the buttons in the Manual screen to feed media
through the DLP-2100. The top buttons operate all motors,
or you can use the other buttons to activate a specific
motor.
Operation is one-way only - you cannot back up the media.
Parameters Screen
The Parameters button is password protected. Changes
should only be made to the parameters under the guidance
of Technical Support.
Diagnostics Screen
The Diagnostics screen displays the current state of the
sensors, motors, and servos.