![Aerotech HPe 150 Hardware Manual Download Page 26](http://html1.mh-extra.com/html/aerotech/hpe-150/hpe-150_hardware-manual_3049258026.webp)
26
Chapter 2
www.aerotech.com
2.1.2. Motor Supply Connections
N O T E :
This product requires two power supply connections. The Motor Supply and Control Supply
must both be connected for proper operation.
Motor power is applied to the Soloist HPe 150/200 Motor Supply connector (refer to
for locations).
Refer to local electrical safety requirements to correctly size external system wires and match wires to
fuses or circuit breakers.
l
The recommended wire size is 8.34 mm2 (#8 AWG).
l
External fuses or a circuit breaker (60 A maximum, time delay type) are required for the AC1, AC2, and
AC3 inputs.
Power for the cooling fan is supplied through the motor supply connection. The fan connects between the
AC1 and AC2 inputs and uses approximately 20W of power.
W A R N I N G : Do not operate the Soloist HPe 150/200 without the safety ground connection in
place.
W A R N I N G : Do not operate the Soloist HPe 150/200 without proper branch protection.
Figure 2-2:
Motor Bus Input Connections
Soloist HPe 150/200
Installation and Configuration