BA Intellidrive User’s Manual
Parameters
Version 1.4
Aerotech, Inc.
4-35
4.5.
Miscellaneous
4.5.1. PRM:200 Position Scale Factor
This parameter allows the user to convert the encoder counts to user units, (i.e., inches,
mm). Refer to Table 4-77 for parameter settings.
Table 4-77.
Settings for Position Scale Factor PRM:200
PRM:200
Settings
Default Value
1.00
Maximum Value
5.0e10
Minimum Value
-5.0e10
Type
Float
Units
-
4.5.2. PRM:201 Default Ramp Time
This is the default ramp time the trajectory generator uses to accelerate the motor if the
ramp time had not been specified (RA command). Refer to Table 4-78 for parameter
settings.
Table 4-78.
Settings for Default Ramp Time PRM:201
PRM:201
Settings
Default Value
.1000
Maximum Value
2.000
Minimum Value
.25e-3
Type
Float
Units
Seconds
4.5.3. PRM:202 Filter Cutoff
This parameter defines the cutoff frequency for the lowpass filter. The low pass filter
filters the current command before it is sent to the amplifier. Refer to Table 4-79 for
parameter settings.
Table 4-79.
Settings for Filter Cutoff PRM:202
PRM:202
Settings
Default Value
500.0
Maximum Value
20000.0
Minimum Value
0
Type
Float
Units
Hz