Parameters
BA Intellidrive User’s Manual
4-32
Aerotech, Inc.
Version 1.4
4.4.4. PRM:94 Unit Address
This parameter defines the address for the unit. When operating in daisy chain, each unit
in the chain must have a unique address. Refer to Table 4-68 for parameter settings.
Table 4-68.
Settings for Unit Address PRM:94
PRM:94
Settings
Default Value
0x41 (A)
Allowable Values
0-Z (0x30-0x5A)
Type
Char (8 bit)
4.4.5. PRM:95 Enable/Disable Daisy Chain - Places in Remote Mode
This parameter enables/disables daisy chain operation. If daisy chain is disabled, the BAI
operates in local mode. Refer to Table 4-69 for parameter settings.
Table 4-69.
Settings for Enable/Disable Daisy Chain PRM:95
PRM:95
Settings
Default Value
0 (daisy chain not enabled, Local mode)
Maximum Value
1
Minimum Value
0
Type
Long (32bit)
Units
-
4.4.6. PRM:96 Autorun Program on Power-Up
This parameter determines if the BAI should begin execution of a program after reset.
The boot program can be found in PRM:97. Refer to Table 4-70 for parameter settings.
Table 4-70.
Settings for Autorun Program PRM:96
PRM:96
Settings
Default Value
0 (do not autoboot)
Maximum Value
1
Minimum Value
0
Type
Long (32bit)
Units
-
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com