Project Maintenance Process
48
Figure 13-1 Layout for Cables of manipulator
Check and Overhaul Process for external Cables
check and repair process as follows:
1.
Adjust the manipulator from J1 to J6's angle is 0°
,0°
,90°
,-180°
,0°
,0°
.
2.
To prevent the damage, please shutdown the electric power and hydraulic
power and pneumatic power of the manipulator.
3.
Check all the external cables for wear or damage.
4.
Check all the cables connector for wear or damage.
5.
Check all the bracket and Tie-down straps are fixed on the operation
6.
Check the fixation between the cable and bracket for wear or damage.
7.
In case of crack, wear or damage, please contact us for replacement
timely
J2 Cable fix
Wrist Cable
J3 Cable fix
Base internal Cable