AIR50-2230A Operation Manual
Calibration of the axes of the AIR50-2230A manipulator
36
Calibration for rough requirements for path positioning accuracy
When the path positioning accuracy is roughly required, the calibration block is
used, as shown in Figure 10-3.
Figure 10-3 Calibration method of zero calibration block
Warning
◼
In the calibration process of the manipulator, the speed should be
reduced as much as possible, and the operator should not enter the
working range of the robot. After each time the robot stops moving, the
alignment of the zero scale on the axis position should be observed.
Caution
◼
When the calibration block is used for calibration of the manipulator, the
basic alignment of the calibration slot shall be observed with the naked
eye, the operating speed of the manipulator is reduced to the manual
lowest gear, and after the position of the fine adjustment shaft, the
calibration block is used for calibration, and the calibration block can be