____________________________________________________________________________________________________
SKY-8101S Manual V04 20180321
Copyright 2016 Advantech Co. Ltd. All rights reserved.
Page 37
Item
Label
Color
Description
A4
MNR
Amber
Minor Alarm
The Minor Alarm LED is ON when the BMC detects a
minor system failure event but such event does not
affect the system’s normal operation. Such events are
defined as any non-critical BMC sensor event (such as
SEL_FULL) being asserted or Case_Intrusion sensor
having triggered.
The MNR LED can be changed to overwrite mode and
turned on or off by the PICMG Set FRU LED State
command. In this mode, BMC does not change the
LED in any condition.
A5
Green
Power State LED
This LED indicates that the unit is powered on. (The
Payload power is on.)
2.4.1.2 Front Button Details
The SKY-8101S supports two buttons at the front which are accessible when the front
cover is open to avoid unintended activation.
A6
A7
Figure 2-5: Front Buttons
Table 2-4: Front Buttons
Item
Element
Description
A6
ID Button
When pressed lights the ID LED