Advanced LAN Bypass User Manual
54
Example
Figure 4.35 Upgrade the MCU FW on Segment 1
4.20
./lbpcu -SRM
Starts monitoring a reset signal on a specified segment if the reset monitoring has not
been enabled yet (cf. Section 3.7.7.1).
Example
Figure 4.36 Start Monitoring Reset Signal on Segment 1
4.21
./lbpcu -GRMS
Retrieves the reset monitoring state on a specified segment (cf. Section 3.7.7.2).
Example
Figure 4.37 Get Reset the Monitoring State on Segment 1
Upgrade the LAN Bypass MCU FW on Segment 1:
root@localhost:~# ./lbpcu -UG 1 lbp_fw_RU_01_20.bin
FW downloading. This process will take 1 ~ 2 minutes.
FW upgrade completed.
root@localhost:~# ./lbpcu -SRM
Example: Start rst monitoring by segment_1. So use -SRM 1 will
start rst monitoring by segment_1.
Command: Start rst monitoring
Syntax: SRM <segment>
Output: Start rst monitoring by which segment.
Error: LBP_ERR_PARAM_OUT_OF_BOUND (0x93)
root@localhost:~# ./lbpcu -SRM 1
Start rst monitoring by segment 1
root@localhost:~# ./lbpcu -GRMS
Example: Rest monitoring state of segment_1 is monitored. So
use -GRMS 1 will get monitored output.
Command: Get rst monitoring state
Syntax: GRMS <segment>
Output: Rest monitoring state
Error: LBP_ERR_PARAM_OUT_OF_BOUND (0x93)
root@localhost:~# ./lbpcu -GRMS 1
Reset Monitoring State: monitored by timeout
Summary of Contents for LAN Bypass
Page 1: ...User Manual Advantech Advanced LAN Bypass...
Page 4: ...Advanced LAN Bypass User Manual iv...
Page 10: ...Advanced LAN Bypass User Manual x...
Page 11: ...Chapter 1 1 ADVANCED LAN BYPASS...
Page 14: ...Advanced LAN Bypass User Manual 4...
Page 15: ...Chapter 2 2 OVERVIEW...
Page 26: ...Advanced LAN Bypass User Manual 16...
Page 27: ...Chapter 3 3 LIBLBPCU ADVANCED LAN BYPASS LIBRARY...
Page 51: ...Chapter 4 4 LBPCU...
Page 79: ...Appendix A A OS limitation...
Page 81: ...71 Advanced LAN Bypass User Manual Appendix A OS limitation...