Advanced LAN Bypass User Manual
48
Example
Retrieve the current WDT status on Segment 1:
Figure 4.15 Get the WDT Status on Segment 1
4.10
./lbpcu -RW
Resets the WDT counter to the initial countdown value and starts the timer (cf. Sec-
tion 3.7.4.3):
Figure 4.16 Usage of the "lbpcu -RW" Command
Example
Reset the WDT to the initial countdown value and then start the WDT on Segment 1:
Figure 4.17 Start WDT on Segment 1
root@localhost:~# ./lbpcu -GW 1
Watchdog Timer Is: Stopped
External WDT pin status: active slave mode
Toggle pin WDT mode: active.
Toggle pin arm status: armed
Toggle pin auto rearm: disabled
Toggle pin status at start up: enabled
Initial Countdown: 100.0 sec
Current Countdown: 0.0 sec
root@localhost:~# ./lbpcu -RW
Example: Reset segment_1 Watchdog counter to the preset value
and start the countdown. So use -RW 1 will rstart countdown on
segment wdt.
Command: Reset and rstart WDT
Syntax: RW <segment>
Output: N/A
Error: LBP_ERR_PARAM_OUT_OF_BOUND (0x93)
root@localhost:~# ./lbpcu -RW 1
root@localhost:~#