Table 4‑1. Construction anchoring chart (Continued)
Wall Structure
Fasteners
Notes
Concrete (minimum 10 cm
(4") thick)
4 fasteners: 3/8" diameter
expansion anchors
Embed the four fasteners a
minimum of 6 cm (2.5"). Follow
the manufacturer instructions. All
fasteners must be installed with
fender washers.
Metal studs (minimum
16 GA)
4 fasteners: 1/4-20 drill flex
self drilling fasteners into
studs or 16 GA backing
Embed the four fasteners 2.5 cm
(1") into the studs. All fasteners
must be installed with fender
washers.
Wood studs
4 fasteners: 3/8" diameter
lag screws into studs of
building
Embed the four fasteners 2.5 cm
(1") into the studs. All fasteners
must be installed with fender
washers.
AC AND DC WIRING FEEDTHROUGH
CAUTION:
For outdoor installations make liquid-tight connections to the unit.
ATTENTION:
Pour les installations extérieures, effectuer des connexions étanches à
l’unité.
The inverter provides feedthrough locations for AC and DC wiring, the
communication cable, and the sensor connection in the bottom service plate of the
connection box. When you select a feedthrough, ensure that the location of the
conduit will not block access to the inverter cabinet. Do not attach conduit to the
cabinet.
☞
Important
All conductors must enter the connection box through the available
feedthrough locations which are for the sole purpose of providing a safe and
convenient way to route wiring in to and out of the inverter. Penetrating the
inverter housing in any other location voids the warranty.
Installing a Feedthrough
TOOLS AND MATERIALS REQUIRED
• NEMA 3R conduit hubs with rubber seals
Advanced Energy
4‑10
Installing
570-1003552-05A
Summary of Contents for AE 3TL 1000 Series
Page 2: ......
Page 12: ...Advanced Energy xii 570 1003552 05A List of Tables...
Page 14: ...Advanced Energy xiv 570 1003552 05A List of Figures...
Page 26: ...Advanced Energy 1 12 Safety and Product Compliance Guidelines 570 1003552 05A...
Page 64: ...Advanced Energy 4 28 Installing 570 1003552 05A...
Page 86: ...Advanced Energy 6 4 Operating the Arc Fault Detection Unit 570 1003552 05A...
Page 92: ...Advanced Energy 7 6 Data Monitoring and Controls 570 1003552 05A...
Page 110: ...Advanced Energy 9 14 Troubleshooting and Solar Energy Technical Support 570 1003552 05A...
Page 116: ...Advanced Energy A 6 Specifications 570 1003552 05A...
Page 120: ...Advanced Energy B 4 System and Mechanical Diagrams 570 1003552 05A...