4. Use the ▲ and ▼ buttons to select the following:
◦
Activation
:
▪
0
= off
▪
1
= on
◦
Send configuration
:
▪
0
= no configuration data in the queue
▪
1
= configuration data being sent
◦
Server IP
: Displays the server IP address
◦
Server port
: Displays the port number of the web server
◦
Portal test
:
Yes
sends a data packet to the web server (portal). There is no
acknowledgement. To verify that the data packet was sent, contact AE Solar
Energy Technical Support.
◦
Password
:
◦
Extended
:
5. Press the enter button to confirm each of the above settings.
6. Press
ESC
to return to the main menu.
DATA LOGGER
The inverter contains an internal data logger which records measured values while
the inverter is running. The data logger uses a circular buffer, which means that when
the memory is full, the oldest data is overwritten. The default configuration includes
16 measurement channels.
Table 5‑5. Data storage
Logging Cycle
Length of Storage Time
1 minute
6 months
5 minutes
2.5 years
10 minutes
5 years
The following parameters are used to set the data logger.
Advanced Energy
5‑16
Operating
570-1003552-05A
Summary of Contents for AE 3TL 1000 Series
Page 2: ......
Page 12: ...Advanced Energy xii 570 1003552 05A List of Tables...
Page 14: ...Advanced Energy xiv 570 1003552 05A List of Figures...
Page 26: ...Advanced Energy 1 12 Safety and Product Compliance Guidelines 570 1003552 05A...
Page 64: ...Advanced Energy 4 28 Installing 570 1003552 05A...
Page 86: ...Advanced Energy 6 4 Operating the Arc Fault Detection Unit 570 1003552 05A...
Page 92: ...Advanced Energy 7 6 Data Monitoring and Controls 570 1003552 05A...
Page 110: ...Advanced Energy 9 14 Troubleshooting and Solar Energy Technical Support 570 1003552 05A...
Page 116: ...Advanced Energy A 6 Specifications 570 1003552 05A...
Page 120: ...Advanced Energy B 4 System and Mechanical Diagrams 570 1003552 05A...