WARNING:
Do not attempt to turn on power until the AE 3TL unit is grounded.
AVERTISSEMENT:
Ne pas mettre l’appareil AE 3TL en marche s’il n’a pas été mis à la terre.
To Start Up the AE 3TL Inverter
1. Verify the connection box cover is secure.
2. Close the AC system circuit breakers or insert the external main fuse.
3. Turn the DC disconnect to the
ON
position.
If the solar modules are receiving sufficient sunlight and no fault exists, the
following sequence will occur:
◦ Self test: All status LEDs light up indicating system initialization. This
process takes approximately five minutes.
☞
Important
On first time startup, this process may take as long as an hour.
◦ System check: After the self test completes, the
Ready
LED flashes
indicating the UL-required five minute system check. The display is lit with
the following information:
F1
F2
ESC
READY
ON
ALARM
EARTH FLT
PAC
0 W
UAC
0.0 V
UDC
0 V
y day
0.0 kWh
Initializing
F1 - Menu
4. Verify that the initialization procedure is complete by checking the following:
◦ Status LED
READY
is continuously lit.
◦ The display begins providing data.
The inverter electronics, the control panel, display, and operating buttons, are
active when DC voltage is applied since they are supplied exclusively from the
DC input.
5. Verify that the startup procedure has started by checking the following:
Advanced Energy
5‑4
Operating
570-1003552-05A
Summary of Contents for AE 3TL 1000 Series
Page 2: ......
Page 12: ...Advanced Energy xii 570 1003552 05A List of Tables...
Page 14: ...Advanced Energy xiv 570 1003552 05A List of Figures...
Page 26: ...Advanced Energy 1 12 Safety and Product Compliance Guidelines 570 1003552 05A...
Page 64: ...Advanced Energy 4 28 Installing 570 1003552 05A...
Page 86: ...Advanced Energy 6 4 Operating the Arc Fault Detection Unit 570 1003552 05A...
Page 92: ...Advanced Energy 7 6 Data Monitoring and Controls 570 1003552 05A...
Page 110: ...Advanced Energy 9 14 Troubleshooting and Solar Energy Technical Support 570 1003552 05A...
Page 116: ...Advanced Energy A 6 Specifications 570 1003552 05A...
Page 120: ...Advanced Energy B 4 System and Mechanical Diagrams 570 1003552 05A...