Single-channel all-digital AC servo drives QS7 Series
25
P25
Analog input method
S, T
0
-
1
0
①
P26
Analog Max. speed
S
1
-
5000
2000
r/min
①
P27
Torque Max. speed
T
1
-
5000
2000
r/min
①
P28
Analog
input
filter
coefficient
S, T
0
-
1000
0
①
P29
Analog input voltage
at zero
S, T
0
①
P30
Inertia ration
P, S, T
0-1000
0
①
P31
Analog
input
percentage
S, T
0-500
0
%
①
P32
Encoder
lines
frequency splitting
P, S, T
0
-
127
0
③
P33
Encoder alarm permit
P, S, T
0
-
1
0
①
P34
JOG speed
S
0
-
5000
1000
①
P35
Internal speed 1
S
0
-
5000
100
r/min
①
P36
Internal speed 2
S
0
-
5000
200
r/min
①
P37
Internal speed 3
S
0
-
5000
300
r/min
①
P38
Internal speed 4
S
0
-
5000
400
r/min
①
P39
Internal position 1
P
0
-
±32000
100
Pulse
①
P40
Internal position 2
P
0
-
±32000
200
Pulse
①
P41
Internal position 3
P
0
-
±32000
300
Pulse
①
P42
Internal position 4
P
0
-
±32000
400
Pulse
①
P43
Communication
address
P, S, T
0
-
255
0
①
P44
Communication baud
rate
P, S, T
9600
①
P45
Torque
reaching
percentage
P, S, T
0
-
100
100
%
①
P46
Torque percentage of
motor stationary
P,
0
-
100
0
%
①
P47
Start
delay
of
electromagnetic brake
P, S, T
0-3200
(
ms
)
0
ms
①
P48
Stop
delay
of
electromagnetic brake
P, S, T
0-3200
(
ms
)
0
ms
①
P49
Zero speed clamp-on
P50
Current loop gain
P, S, T
10-4000
600
①
P51
Current loop integral
P, S, T
1-2000
150
①
P52
Encoder lines
P, S, T
1000
-
6000
2500
③
P53
Encoder type
P, S, T
0
-
1
0
③
P54
Pole-pairs
P, S, T
2
-
6
4
③
P55
Drift angle
P, S, T
0—2500
2360
③
P56
Rated current
P, S, T
0
-
100
28
0.1A
③
P57
Rated torque
P, S, T
0
-
200
13
0.1NM
③
P58
second electronic gear
radio numerator
P
0-32000
①
P59
second electronic gear
radio denominator
P
0-32000
①