Single-channel all-digital AC servo drives QS7 Series
6
2.1.4 Multi- drivers install
2.2 Servo motor’s install
● Working environment temperature
:
0~45
℃;
Work environment humidity
:
lower than 40%
~80% (
non condensing
).
● Storage environment temperature
:
-40~55
℃;
Storage environment humidity
:
lower than
80% (
non condensing
).
● vibrate
:
lower than 0.5G
。
● Avoid direct sunlight
。
● Prevent oil mist
、
erosion of salt
。
● Prevent corrosive liquid
、
gas
。
2.3 Notice of installment
Do not hit motor or motor shaft while disassembling pulley, in order to prevent encoder
from damage; use spiral drawing tools for disassembly;
Prohibit large axial and radial load on motor; suggest to select flexible coupling to connect
the load;
Fix motor with washer fastening to prevent the motor from loosing.