![Adtech QS7 Series Manual Download Page 38](http://html1.mh-extra.com/html/adtech/qs7-series/qs7-series_manual_2854163038.webp)
Single-channel all-digital AC servo drives QS7 Series
33
P55
Drift angle
Only if motor type is set to be
(
P2=9999
)
, this self-
defined parameter will be valid.
Set value refers to drift angle between motor angle and
zero point;
Please note that this parameter will be valid after it is
modified and saved, and then restart the machine;
Default value is 2360.
0
-
2500
P56
Rated
current
Only if motor type is set to be
(
P2=9999
)
, this self-
defined parameter will be valid.
Set value refers to the motor rated current size, to only
impact on the protective function of motor current
without impact on motor operational effect;
Setup unit
(
0.1A
)
.
0
-
100
P57
Rated
torque
Only if motor type is set to be
(
P2=9999
)
, this
parameter will be valid.
Set value refers to the motor rated torque size, to only
impact on the protective function of torque control
without impact on motor operational effect;
Setup unit
(
0.1A
)
.
Self-defined unit (0.1Nm)
0
-
200
P58
second
electronic
gear radio
numerator
use method is same as first electronic gear radio .
P59
second
electronic
gear radio
denominat
or
use method is same as first electronic gear radio .
0
-
1
P60
filter
coefficient
adopt to remove the motor voice lead by speed loop gain too
big
0—9
P61
Drive
current
type
0 refers to QS6AA015M above; 1 refers to QS6AA010M.
0
-
1
P62
V-phase
current
zero
correction
It refers to drift value of V-phase current zero
2008
-
2088
P63
W-phase
current
zero
correction
It refers to drift value of W-phase current zero
2008
-
2076
Note:
It is recommended that all parameter settings and modification should be implemented
when the motor is prohibited.
All parameters (only P2 parameter will be effective after re-electrified when disconnecting
power) settings will be effective after just pressing "Enter", without re-electrifying;
however, parameter writing should be performed for long-term preservation;