Troubleshooting table
Error
Remedy
Video and Drive led do
not flash
No “
Railroad
” flashing
Make sure “boot key” is installed and unit has been reset. If this is
correct, then make sure the “boot key” shorts pins 9 to 4. NOTE: If
you are using the dail-up method to upload Firmware, the “Railroad”
pattern will not show on the unit.
Unit will not connect
Make sure location is set up for proper baud, d ata, stop and parity
along with proper communications port. Also make sure the unit name
is “*”. The “*” star or asterisk symbol is the wild card name. It will
allow the Symphony-Net to communicate to a Mirage/Soloist 2
without regard to the unit name.
Unit will not program
Make sure the communications port is configured properly, that all
cables are correctly installed and the “boot key” has been installed and
unit was reset after the “boot key” was installed.
After a successful
program, another unit
can not be programmed.
Early releases of the IFP applet could only program one unit at a time.
To use this early version with multiple units, you must close the IFP
applet and disconnect. Re -open the IFP applet and re-connect prior to
each programming session. It is strongly recommended to have
ADTEC e-mail the new Symphony-Net software. See note below on
“Boot Code” firmware programming.
Unit will not operate
after being programmed
Remove the “boot key” and power unit off and back on. Then re-
connect with the proper location selected and use Control Console to
control the unit.
Unit does not play
video after start up
Connect to the unit with the Control Console. Erase the list saved in
NV memory. Then issue a play command.
M
M
Warning: Files in a list that no longer reside on a drive will
cause the unit to lock up!
M
M
Warning:
Never program the “Boot Code” firmware in the field. Doing so
will render the unit DEAD. It will have to be returned to ADTEC for reprogramming. If using
the old version of Symphony-Net with the IFP module that has the “Boot Programming”
option, please contact ADTEC to receive the new copy.
Old IFP applet screen with “Boot Code” option.
NOTE:
If you have a version of Symphony with this type of
screen, please contact us and upgrade your software.