14-1
BATTERY, CHARGE, AND IGNITION SYSTEM
BATTERY
Remove the battery
•
Take off the battery fixed plate.
•
Disconnect
the
−
wire (GR) than the
+
wire
(RD).
*
Beware not to contact with frame
body when disconnect the
+
terminal.
It will damage the battery even the
flaming will cause fire with gasoline.
•
Check the voltage after disconnected.
•
Measure the voltage from both
terminals.
Fully charged: 12.8V
Charge insufficient: 12.0V
*
Connect the
+
wire (RD) than the
−
wire (GR) to avoid short circuit.
•
Installation based on reversed
procedure.
CHARGE
Connection: C to b
Charger
−
to battery
−
*
Avoid any flaming material around
the battery.
*
Turn off the charger, before start or
after finish the charge operation. The
spark may cause explosion during
connecting.
*
Please follow the charge instruction
on battery as the operation standard.
*
Don’t use quick charge unless urgent.
*
Measure the voltage after finish
charge for 30 minutes.
Charge current: standard: 0.7A
Charge time:
standard: 5~10 Hr.
Battery voltage: above 12.8V
battery fixed plate
battery