4-1
LUBRICANT SYSTEM
Information for Operation
ENGINE OIL & FILTER
Oil quantity
*
When you check the oil quantity, the
vehicle have to stand on flat ground.
*
Starting the engine about 2~3 min..
then stop it. After 2~3 min. check the
oil quantity.
•
Remove the oil level gauge and check
If the oil level under the lower limit then
add the standard oil to upper limit of
gauge.
Oil Exchange
*
The motor oil will flow more easily if
the engine is warm.
•
The oil release nut is under R-crank
case cover. Take-off the oil-filter
cover can have better release of the
oil.
•
Check the O-ring of oil filter cover.
Replace new ring if it’s damaged.
•
After cleaning the filter, then
mounting the oil filter, filter spring
and
cover.
Locking torque: 1.5 kg-m
•
Adding the proper oil quantity:
engine disassembly
:
0.9L.
change
:
0.75L
•
Check the engine oil whether leaking.
If not then starting the engine at idle
speed for few minutes and checking the
oil level again.
oil level gauge
Oil filter cover
O-ring